Thứ Hai, 5 tháng 8, 2019

Chỉ số mở cửa nước - Water Gate Opening Indicator - GICW-S1-11 - Takuwa Vietnam - STC Vietnam

Công ty TNHH TM DV Song Thành Công
Liên hệ: 091 515 9944
********************

Chúng tôi xin gửi đến quý khách hàng dòng sản phẩm tối ưu cho các ứng dụng công nghiệp.


Water Gate Opening Indicator

Water gate indicator is important equipment for control of water gate on dam and river weir etc.
We have a lineup of indicators and converters which are suitable for purpose and site condition.

Signal Converter (GICW Series)

GICW series is a signal converter from Synchro to Digital for output to external equipment.
It has many useful functions for adjustment of gate opening indicator.
Non-linearity scale conversion table can be set up and it is suitable for the radial gate.

Features

  •   ・Conversion from the Synchro to the BCD signal (by Absolute value)
  •   ・Arbitray scale adjustment (Zero adjustment, Free scale, Level offset)
  •   ・Non-linearity scale conversion table can be set up easily by PC software and installed
          it to the GICW through the SD card
  •   ・Self-Diagnosing function (ERR code is displayed)
  •   ・Small size and lightweight 

Available sites

  •  ・Water gate opening indicator which is using a synchronous motor

Main specification

Type GICW-S1-□□ GICW-S2-□□
Power Supply
AC90V~AC242V, 50/60Hz
Current consumption
30VA or less
Ambient temperature
-10ºC ~ 50ºC
Data output rang
±99999
Conversion accuracy ±0.1%FS ±0.003%FS
Input signal Synchro 3-wire signal
Max.90V/Input synchro
1unit (1st gear)
Synchro 3-wire signal
Max.90V/Input synchro
2unit(2nd gear)
Data output signal
1.BCD: 5digit x 2
 -Each digit odd parity, BUSY, Signal error,Dropping voltage
 -Output condition: A contact with non-voltage
2.RS-232C(no control sequence) x 1
3.Power discontinuity contact x 1
 -Output condition: Make when electric outage
4.Compare contact: x 16
  -Output condition: A contact with non-voltage 
Input scale conversion 0~1999/Rev 0~20000/Rev
Throughput performance                
Level calculation: -999.99m~+999.99m
Hold: maximum / minimum
Zero point adjustment: by setting SW in the front of body
Data output direction can be set
Self-diagnosing trouble: power off, signal error, dropping voltage
Non-linearity scale conversion by correction table
SD card
Usable card: 2GB or less
Data transfer distance
Input: Max. 1km (2mm2 wire in use)
Options

 Model name: GICW-[AB]-[CD]

Code Option Type Option Detail Number
[AB] Input signal S1:Synchro 3-wire signal Max.90V/Input synchro 1unit
S2: Synchro 3-wire signal Max.90V/Input synchro 2units
[CD] Output signal 11: BCD Output x 1 Compare contact output x 1
20: BCD Output x 2

Không có nhận xét nào: